Radon Mitigation Before & After Photos
Click on a photo to enlarge.
Radon Mitigation System Installed in Guilford Home Office Basement
Before
The home had a radon level of 6.9 pCi/L with no mitigation system in place. The basement was being used as a home office area, increasing the importance of improving indoor air quality.
After
A one-pipe radon mitigation system was installed near the boiler closet and routed through the drop ceiling to the exterior for effective radon reduction.
Radon Fan Installation in Madison
Before
The home was scheduled for a radon fan installation using a FanTech fan ordered specifically for the project. The existing setup was reviewed before completing the work.
After
The FanTech fan was installed as planned. No unexpected changes to the job were reported, and the installation was completed without a need for additional follow-up.
Three-Point Radon Mitigation System Planned for Historic Madison Home
Before
This 1880 home in Madison is approximately 1,500 square feet and has a partially finished basement. Radon readings have been around 3–4 pCi/L. A footing separates the finished and unfinished basement sections. There are no crawl spaces or sump pump, and some exposed dirt may be present along the fieldstone walls in the unfinished area.
After
Install a three-point radon mitigation system with extraction points in the finished basement, mechanical room, and workout room. The system layout and exterior exhaust route will be discussed with the homeowners before installation so everyone is comfortable with the proposed design.
We will also address any exposed dirt found along the fieldstone walls in the unfinished section, including encapsulation where needed. After installation, follow-up radon testing will help determine how effectively the system is reducing radon levels.
One-Point Radon Mitigation System Installed in Madison
Before
The home tested at 7.0 pCi/L after the homeowner recently moved in. There was no existing radon mitigation system, sump pump, or WaterGuard system. The basement had no visible cracks noted during the initial assessment.
After
A one-point radon mitigation system was installed at the rear of the home. The extraction point was placed in the closet near the sewer pipe, using gravel beneath the foundation to support airflow. A Festa Hawk fan was installed to create the suction needed to draw radon from beneath the home and vent it safely outdoors. Follow-up radon testing is recommended to confirm the system’s effectiveness.
One-Point Radon Mitigation System Installed in Madison
Before
Radon readings in the partially finished basement were both above and below 4.0 pCi/L. The home is a ranch with no crawl space or sump pump, and the basement is planned for use as an office. A mitigation system was recommended to help reduce radon levels in the space.
After
A one-point radon mitigation system was installed with a Festa Hawk fan. The extraction point uses the available dirt and gravel beneath the foundation, and the piping exits at the rear of the home near the sink before following the corner of the sunroom. A follow-up radon test is recommended to confirm the system's performance and measure the levels after installation.