Apex Radon Solutions Before & After Photos

Click on a photo to enlarge.

One-Point Radon Mitigation System Installed in Ridgefield

Before

This Ridgefield home is an unfinished Cape-style house built around 1960, with a measured radon level of 6.9 pCi/L, above the EPA’s recommended action level of 4.0 pCi/L. The home has no crawl space or sump pump. Cracks in the concrete floor provided areas for sealing as part of the mitigation work.

After

A one-point radon mitigation system was installed, with the extraction point positioned near the main beam and piping routed toward the right side of the house. Approximately 50 feet of floor cracks were sealed to help limit soil-gas entry. The installation works with the home’s existing foundation layout, and follow-up testing can help confirm how effectively radon levels have been reduced.

Radon Fan Replacement and Crawl Space Mitigation Upgrades Completed in Ridgefield

Before

The home relied on an aging radon fan and had two dirt crawl spaces that were not fully incorporated into the mitigation system, limiting overall radon collection efficiency.


After

 

A new radon fan was installed, and both crawl spaces were integrated into the mitigation system with dedicated piping to improve radon collection and long-term system performance.

Two-Pipe Radon Mitigation System Installed in New Fairfield Colonial Home ( Exterior)

Before

The exterior of the home had no radon mitigation system in place. The siding area was clear, with no piping installed for venting.


After

 

A radon mitigation pipe was installed along the exterior of this New Fairfield colonial home, routed vertically and vented above the roofline. This pipe connects to one of the system points installed in the unfinished basement and provides proper airflow for the system.

Two-Pipe Radon Mitigation System Installed in New Fairfield Colonial Home (Interior Basement)

Before

The unfinished portion of the basement had no radon mitigation system in place. The space included existing equipment and limited room for pipe routing.


After

 

A radon mitigation pipe was installed in the unfinished basement, carefully routed through the space to work around existing equipment. This is part of a two-pipe system, with one pipe positioned near the basement door and another tucked behind the chimney to provide full coverage.

Three-Pipe Radon Mitigation System Installed with Crawl Space and Shed Venting in New Canaan

Before

The home had a radon level of 4.0 pCi/L with a crawl space and slab configuration, and no mitigation system in place.


After

A three-pipe radon mitigation system was installed, with coverage across the closet, slab, and crawl space. The system was routed through a shed for fan placement and vented through the shed roof.