Two-Point Radon Mitigation System Installed in Easton
Before
This Easton home had radon readings ranging from 2.8 to 6.0 pCi/L, with some measurements exceeding the EPA’s recommended action level of 4.0 pCi/L. The foundation has gravel beneath the slab, and the home’s tall roof required careful planning for the exterior vent route. The homeowner also identified additional requests involving a manometer alarm, ductwork sealing, and a custom wire-mesh critter guard.
After
A two-point radon mitigation system was installed using a Festa Hawk fan. The exterior piping runs alongside the HVAC units and continues up and over the tall roof to vent soil gases outdoors. The installation was completed without changes or unusual conditions. Follow-up radon testing is recommended to evaluate the system’s performance.
Radon Fan Replacement Completed in Southport Home
Before
The existing radon system had an older fan that had never been serviced, while radon levels were averaging between 5 and 10 pCi/L.
After
The older radon fan was replaced with a new fan, restoring reliable operation of the existing mitigation system.
Radon Mitigation System Installed in Goshen Slab Home
Before
The home had a radon level of 2.2 pCi/L with no mitigation system in place. The structure is slab-on-grade, with an inaccessible crawl space below.
After
A single-pipe radon mitigation system was installed, with the pipe routed through the right side of the home to provide proper venting.
Radon Mitigation System Installation in Lakeside
Before
The home had an elevated radon reading of 10.5 pCi/L. The unfinished basement and crawl spaces presented multiple potential areas for radon entry, requiring a system designed to address each section.
After
The four-point radon mitigation system was installed to draw radon from the main foundation and both crawl spaces. The completed system includes an exterior fan and vent piping routed along the home's exterior. A pressure gauge was installed on the system to help monitor operation.
Radon Mitigation System Replacement Planned for Lakeside Home
Before
The existing radon fan is mounted outside the bedroom and creates unwanted noise inside the home. The current system will need to be removed or disconnected as part of the planned relocation.
After
Install a replacement radon mitigation system near the boiler, with exterior piping routed above the Bilco doors and upward between the windows above the lower metal roof. Reuse existing PVC piping where appropriate, install anti-vibration clamps and a muffler to help reduce noise, and cap off the old exterior pipe.